Baader MPCC Mark III V-1 Newtonian Coma Corrector Set - visual and photographic Version
This corrector eliminates the coma that occurs in Newtonian telescopes, thus creating pinpoint stars over the entire field of view.♦ photographically and visually usable
♦ no extension of the focal length and therefore no reduction of the field of view
♦ very well usable from 1:3.5 to 1:6
♦ photographic connection T2 and M48 (2" filter thread)
♦ visual connection 2" and 1.25"
♦ telescope connection via 2" barrel with filter thread
♦ thanks to redesigned, larger lenses in this area very sharp and completely free of vignetting
♦ Phantom Group™ multi-coated, for highest transmission and reflection-free
♦ adjustable optical length
♦ eyepieces, cameras and similar accessories not included
Baader MPCC Mark III V-1 Newtonian Coma Corrector Set - visual and photographic Version
Newtonian telescopes are excellent for astrophotography. However, the coma of these telescopes must be corrected. This error shows up as a distortion of the stars towards the edge. The error increases with the speed of the telescope and with the size of the camera sensor.
The Multi Purpose Coma Corrector MARK III (MPCC III) virtually eliminates the coma of fast Newtonian telescopes without changing the focal length. The unique lens arrangement has Phantom Group Coating™ on all glass-to-air surfaces, providing highest transmission over a very wide spectral range from UV to NIR. The Mark III version of the MPCC can be used on mirrors from f/3.5 to f/6 and fits practically all 2" focusers and off-axis guiders. Stars remain pinpoint across the entire field of view, even the notorious central soft spot is eliminated.
Photographic Application
The base-element 2858400A is prepared for use with a DSLR and a standard T-ring, it can be used over the T2 thread on all standard T-rings. Since the T-thread vignettes with cameras with larger sensors (such as full-format DSLRs), the T2 thread can be removed. Then an M48 thread is free, and the free aperture increases from 38 to 44 mm. The M48 spacer ring for MPCC III / Protective EOS T-ring can be connected directly to the Protective CANON DSLR T-ring.
This means that you do not only have sharp stars in the entire picture but also illuminate large sensors!
The flange focal distance is 55 mm with the T2 thread or 58 mm for the M48 thread.
Visual and photographic application
In addition, the MPCC can be used both visually and photographically. The V-1 set # 2454803 contains the necessary adapters for most eyepieces or cameras with a 1.25" barrel - a detailed description can be found in the manual. The basic element of the MPCC can be upgraded at any time for visual use, all necessary parts are also available separately.
Technical data of MPCC Mark III
♦ Phantom Coating™ Group multicoated for maximum transmission and freedom from reflections from UV to NIR
♦ no reflections even when using nebula filters and interference filters.
♦ no change in focal length or field size, an f4 Newtonian remains f4!
- extremely variable, for visual and photographic use
♦ large lenses for completely vignetting-free images up to f/3.5
♦ maximum sharpness across the field - without center soft spot (as reported of other)
♦ can be used with Newtonian telescopes from f/3.5 to f/6 - the MPCC fits all 2" focusers
♦ 2" stopping collar removable for increase in backfocus
♦ adjustable optical length
♦ with additional 2" filter thread on the telescope side
♦ accepts T2 (M42x0.75) and/or 2" (M48x0.75) threaded adapters
♦ sensors up to full-frame size are illuminated, for full-frame size we recommend the M48 adapter for the camera.
♦ optional adapter for direct coupling of the MPCC III directly onto the Baader CANON EOS protective T-ring
♦ 44 mm clear aperture when using the M48(2") filter-tread or the Protective T-ring with optional adapter
♦ easy to use
♦ exceptional price/performance ratio
Optical design: | Coma Corrector |
Working range: | f/3.5 – f/6 |
Change focal length: | 100% (no change) |
AR coating: | Phantom Group Coating® |
Inner diameter / clear aperture (mm): | 44 (with M48 connection) |
Inner connection (lens sided): | Thread, M48 |
Outer connection (lens sided): | Barrel, 2" (50.8 mm) |
Inner connection (eyepiece/camera-sided) Clamp, 1.25": | |
Outer connection (eyepiece/camera-sided) Thread, T2 (M42x0.75), M48: | |
Clamping system: | Screw clamps |
Weight (kg): | 0.274 |
In the box:
♦ MPCC Multi-Purpose Coma Corrector
♦ Focusing Eyepiece Holder
♦ Extension Tube, lockable
♦ Stop Ring